<td id="vo9pt"></td>
<i id="vo9pt"></i>

<sub id="vo9pt"></sub>

    1. ?

      Oil cooling machine



      Lubricating oil, hydraulic oil, machine tool spindle and hydrostatic pressure system and other special oil coolers (also known as cold oil machine, constant temperature tank, hydraulic tank coolers, spindle oil coolers).

      ■ The main function

      1, prevent machine tool thermal deformation 2, prevent machine tool spindle center offset 3, prevent oil oxidation, evaporation

      4, stable oil pressure, prevent oil shock 5, improve machine tool processing accuracy 6, prolong equipment, tool life


      ■  The main features

      1, the main components are imported components, refrigeration power margin is increased, to ensure service life and apply to bad conditions, stable performance, high reliability.

      2, microcomputer control, a variety of intelligent protection, with fault location alarm display; Provide passive contact and remote control (optional), optional RS485 communication interface, intelligent interconnection and other functions, can be connected with the control system of machine tools, constitute a closed loop monitoring, improve system reliability. Optional repeater to connect to the cloud for remote intelligent monitoring and operation, convenient maintenance.

      3, with conventional precision, high precision control and variable frequency model optional, oil temperature control accuracy can reach ±1℃, ±0.5℃, ±0.1℃ respectively.

      4, the machine is complete, cooling capacity covering 0.6~260KW. Applicable to various departments of different requirements and working conditions;

      A. It has two temperature control modes of "room temperature homology" and "temperature fixed" at the same time, which can be converted according to actual needs.

      B. Hot and cold models are optional. Heat when the oil temperature is lower than 10℃ and stop heating when it reaches 13℃. In addition, high temperature units can be customized.


      ■ Scope of application

      All kinds of mechanical equipment, such as machine tool spindle, dynamic and static pressure system or hydraulic box, reduction box, lubricating oil box, gear box and other kinds of cooling oil box, etc.

      ■ Specifications and parameters

      Product model

      LO-10

      LO-15

      LO-25

      LO-35

      LO-50

      LO-70

      LO-100

      LO-120

      LO-150

      LO-180

      LO-200

      LO-250

      LO-300

      LO-350

      LO-400

      LO-500

      LO-600

      LO-800

      LO-1000

      Cooling capacity(W)

      1000

      1500

      2500

      3500

      5000

      7000

      10000

      12000

      15000

      18000

      20000

      25000

      30000

      35000

      40000

      50000

      60000

      80000

      100000

      Heating capacity(W)

      1000

      1500

      2500

      3500

      5000

      7000

      10000

      12000

      15000

      18000

      20000

      25000

      30000

      35000

      40000

      50000

      60000

      80000

      100000

      The power supply

      3P~50Hz 380V

      The total
      work
      The rate of
      (W)

      LO-□

      690

      1080

      1490

      1845

      2680

      3110

      4570

      5300

      5960

      7140

      7880

      10530

      11760

      15230

      15760

      21060

      23520

      31590

      35280

      LO-□P

      880

      1490

      1900

      2760

      4650

      5125

      7600

      8320

      8980

      12500

      13230

      15890

      17120

      20580

      26460

      31780

      34240

      47670

      51360

      LO-□PT

      880

      1490

      1900

      2760

      4650

      5125

      7600

      8320

      8980

      12500

      13230

      15890

      17120

      20580

      26460

      31780

      34240

      47670

      51360

      LO-□P2T

      1290

      1490

      1900

      2670

      4650

      7140

      10370

      11290

      11940











      The total
      electricity
      flow
      (A)

      LO-□

      1.7

      2.5

      3.8

      4.5

      5.2

      5.9

      10.4

      13.2

      14.3

      19.4

      20.4

      26.0

      27.0

      30.2

      40.8

      52.0

      54.0

      78.0

      81

      LO-□P/PT

      2.7

      4.0

      5.4

      7.0

      9.6

      10.2

      16.4

      19.4

      20.4

      29.0

      30.0

      35.8

      37.0

      39.8

      60.8

      71.6

      74.0

      107.4

      111

      LO-□P2T

      4.2

      4.0

      5.4

      7.0

      9.6

      14.7

      22.5

      25.4

      26.4













      Temperature control range

      Temperature fixed 15 ~ 45℃/ room temperature homology type (room temperature +T*)℃ control accuracy ±1℃

      make
      with
      article
      a

      At room temperature(℃)

      5~50

      The oil temperature(℃)

      5~55

      Using liquid

      Hydraulic oil, lubricating oil, spindle oil, etc

      Piping dimensions (internal thread)

      G3/8"

      G1/2"

      G3/4"

      G1"

      G11/4"

      G11/2〝

      G2"

      DN65 PN1.6MPa法蘭

      Tank volume(L)

      12

      15

      25

      35

      45

      60

      80

      100

      120

      150

      180

      200

      250

      250

      300

      350

      420

      500

      550

      Protection device

      Overload protection of compressor * overload protection of oil pump * high and low pressure protection * Anti-freezing protection * motor reverse phase sequence and missing phase protection * liquid level and flow detection * abnormal alarm


      Note :(1) the above cooling capacity is based on the ambient temperature of 35℃, the inlet oil temperature of 35℃, using ISO VG32 oil.

      (2) The temperature control mode of the unit is divided into two types: fixed temperature and room temperature harmonization. Users can choose to adjust and convert according to their needs. The lower limit of the two temperature control modes is 15 ° C, and T*=-9 ° C to +9 ° C.

      (3) The heating capacity refers only to LOR cold and hot units. The heating capacity is based on the ambient temperature of 13℃ and the oil inlet temperature of 13℃. (optional)

      Our company accepts orders of special specifications. The parameters in this table are subject to change without prior notice. The product nameplate shall prevail.